research article

Simultaneous Estimation of Chlorzoxazone Paracetamol Famotidine and Diclofenac Potassium in Their Combined Dosage Form by Thin Layer Chromatography

Authors: Usmangani K Chhalotiya*, Dhruv B Patel, Dimal A Shah, Falgun A Mehta, Kashyap K Bhatt

*Corresponding Author: Usmangani KC, Indukaka Ipcowala College of Pharmacy, Department of Pharmaceutical Chemistry and Analysis; E-Mail: usmangani84@gmail.com

Received Date: 19 November, 2016

Accepted Date: 21 February, 2017

Published Date: 28 February, 2017

Citation:

Usmangani KC (2017) Simultaneous Estimation of Chlorzoxazone Paracetamol, Famotidine and Diclofenac Potassium in Their Combined Dosage Form by Thin Layer Chromatography. J Pharma Pharma Sci 02: 111. DOI: https://doi.org/10.29011/2574-7711.100011

Abstract

A sensitive, selective and precise high performance thin layer chromatographic method has been developed for the estimation of chlorzoxazone, paracetamol, diclofenac potassium and famotidine in the pharmaceutical dosage form. TLC aluminum plates pre-coated with silica gel 60F254 used as the stationary phase, while chloroform: methanol: ethyl acetate: hexane: ammonia (10: 2.5: 1.5: 1: 0.1, v/v/v/v/v) used as mobile phase. The Rf values were observed 0.74 ± 0.01, 0.52 ± 0.01, 0.30 ± 0.01 and 0.14 ± 0.01 for chlorzoxazone, paracetamol, diclofenac potassium and famotidine, respectively. The densitometry analysis was carried out in absorbance mode at 282 nm. The method was linear in the range of 250-1500 ng/spot for chlorzoxazone, diclofenac potassium and famotidine and 500- 3000 ng/spot for paracetamol and method was validated as per ICH guideline. The limit of detection and limit of quantization were found to be 35.98 ng/spot and 109.05 ng/spot, respectively for chlorzoxazone, 99.74 ng/spot and 302.25 ng/spot, respectively for paracetamol, 58.63 ng/spot and 177.69 ng/spot, respectively for diclofenac, and 50.93 ng/spot and 154.35 ng/spot, respectively for famotidine. The proposed method was successfully applied to the estimation of chlorzoxazone, paracetamol, diclofenac potassium and famotidine in the pharmaceutical dosage form.

Keywords: Chlorzoxazone Paracetamol; Chlorzoxazone (CLZ); Paracetamol (PCM); Diclofenac potassium (DCL); Famotidine (FAM); HPTLC; Validation; Chlorzoxazone Dosage

Introduction

Chlorzoxazone (CLZ) is chemically 5-chloro-2, 3-dihydro-1, 3-benzoxazol-2-one. The empirical formula of CLZ is C7H4ClNO2 and a molecular weight is 169.56 g/mol. It is NSAID. It inhibits multisynaptic reflex a.c. involved in producing and maintaining skeletal muscle spasm. Paracetamol (PCM) is chemically N-(4-hydroxyphenyl) acetamide. The empirical formula for PCM is C8H9NO2 and a molecular weight is 151.163 g/mol. It inhibiting both is forms of cyclooxygenase; COX-1, COX-2, and COX-3 enzymes involved in prostaglandin (PG) synthesis. Diclofenac potassium (DCL) is chemically 2-{2-[(2, 6-dichlorophenyl) amino] phenyl} acetic acid and empirical formula of DCL is C14H11Cl2NOand molecular weight is 318.13g/mol. It inhibition of leukocyte migration and the enzyme cylooxygenase (COX-1 and COX-2), leading to the peripheral inhibition of prostaglandin synthesis. Famotidine (FAM) is chemically 3-[({2-(diaminomethylidene) amino]-1, 3-thiazol-4-yl} methyl) sulfanyl]-N' sulfamoylpropanimidamide and empirical formula for FAM is C8H15N7O2S3 and molecular weight is 337.44 g/mol. It is competitive

Histamine H2-receptor antagonist and inhibits many of the isoenzymes of the hepatic CYP450 enzyme system.

The combined dosage form of CLZ, PCM, DCL and FAM is used as muscle relaxant. CLZ, PCM, DCL and FAM are official in United State Pharmacopoeia and British Pharmacopoeia. Official method has been reported for CLZ, PCM, DCL and FAM in United State Pharmacopoeia and British Pharmacopoeia. Some of UV, HPLC, TLC methods has been reported for the estimation of CLZ, PCM, DCL and FAM alone and with other drug combination. No method has been reported for the estimation of CLZ, PCM, DCL and FAM in their combined dosage form [1-27]. In comparison to LC and LC-MS/MS methods, HPTLC method is considered to be a good alternative, and it should be widely explored as an important tool in routine drug analysis. A major advantage of HPTLC is its ability to analyze several samples simultaneously using a small quantity of mobile phase. This reduces the time and cost of analysis.

Experimental

HPTLC instrument

The samples were applied in the form of a bands of width 8 mm with a Camag 100 μl sample syringe (Hamilton, Switzerland) using Camag Linomat 5 (Switzerland) sample applicator on pre-coated silica gel aluminum plate 60 F254 (10 cm x 10 cm with 0.2 mm thickness, E. Merck, Germany). Camag TLC scanner 4 was used for the densitometric scanning.

Chemicals and reagents

Analytically pure CLZ, PCM, DCL and FAM from Sun pharmaceutical industry ltd. Vadodara, India were obtained as gift samples. Methanol (AR grade) of SRL Private Ltd. and chloroform of Chemdyes Corporation (AR grade) were used. Ammonia and hexane of Chiti-Chem Corporation (AR grade) were used. Ethyl acetate of Astron Chemicals (AR grade) Tablet formulation fast ran MR (Horizon biocauticals Pvt. Ltd.) containing 500 mg of PCM, 250 mg CLZ, 50 mg DCL and 10 mg FAM was procured from local pharmacy

Chromatographic System

Sample application

Standards and formulation samples of CLZ, PCM, DCL and FAM were applied on the HPTLC plates in the form of narrow bands of 6 mm length, 10 mm from the bottom and left edge, and with 9 mm distance between two bands. Samples were applied under a continuous stream of nitrogen gas.

Mobile phase and development

Plates were developed using a mobile phase consisting of chloroform: methanol: ethyl acetate: hexane: ammonia (10: 2.5: 1.5: 1: 0.1, v/v/v/v/v). Linear ascending development was carried out in a twin-trough glass chamber equilibrated with the mobile phase vapors for 30 min at 25 ± 20C. Ten milliliters of the mobile phase (5 ml in the trough containing the plate and 5 ml in the other trough) was used for each development and was allowed to migrate a distance of 80 mm, sample application rate is 200nl/sec. After development, the HPTLC plates were dried completely using continuous stream of nitrogen.

Densitometric analysis

Densitometric scanning was performed in the absorbance mode under control by win CATS planar chromatography software. The source of radiation was the deuterium lamp and bands were scanned at 282 nm. The slit dimensions were 6 mm length and 0.45 mm width, with a scanning rate of 20 mm/s. Concentrations of the compound were determined from the intensity of diffusely reflected light and evaluated as peak areas against concentrations using a linear regression equation.

Preparation of standard stock solution

PCM (10 mg), CLZ (5 mg), DCL (5mg) and FAM (5mg) were accurately weighed and transferred to 10 ml volumetric flasks and dissolved in few ml of methanol. Volumes were made up to the mark with methanol to yield a solution containing 1000mg/ml of PCM and 500 mg/ml of CLZ, DCL and FAM. Aliquot from the stock solutions of PCM, CLZ, DCL and FAM were appropriately diluted with mobile phase to obtain working standard of 100 mg/ml of PCM and 50 mg/ml of CLZ, DCL and FAM respectively.

Validation

Validation of the developed HPTLC method was carried out according to International Conference on Harmonization (ICH) guidelines Q2 (R1) for specificity, sensitivity, accuracy, precision, repeatability, and robustness [28].

Linearity of calibration curves

Linearity of the method was evaluated by constructing calibration curves at six concentration levels over a range of 500–3000 ng/band for PCM and 250-1500 ng/band for CLZ, DCL and, FAM by applying 5ml to 30ml from stock solution has been applied on HPTLC plate using sample applicator. The calibration curves were developed by plotting peak area versus concentration (n = 6) with the help of the win CATS software.

Accuracy

Accuracy is closeness of the test results obtained by the method to the true value and should be established across specified range of analytical Procedure. The accuracy of the method was determined by calculating recoveries of PCM, CLZ, DCL and FAM by method of standard additions. Known amount of PCM (0, 500, 1000, 1500 ng/spot) and CLZ, DCL and FAM (0, 250, 500, 750 ng/spot) were taken from the working standard solutions (1000 ng/spot of PCM and 500 ng/spot of CLZ, DCL and FAM respectively). It was added to a pre quantified sample and the amount of PCM, CLZ, DCL and FAM were estimated by measuring the peak area and by fitting these values to the straight-line equation of calibration curve. The proposed acceptance criteria for the accuracy studies are ranges from 95-105 %.

Precision

Precision is closeness of agreement (degree of scatter) between a series of measurements obtained from multiple samplings of the same homogeneous sample. Precision was evaluated in terms of intraday and interday precisions. Standard solutions of 100 mg/ml of PCM and 50 mg/ml of CLZ, DCL, and FAM, were prepared and used for the precision study. Intraday precision was determined by analyzing sample solutions of PCM (500 ng/spot, 1000 ng/spot, and 3000 ng/spot), CLZ, DCL and FAM (250 ng/spot, 750 ng/spot, 1500 ng/spot) at three levels covering low, medium, and high concentrations of the calibration curve three times on the same day. Interday precision was determined by analyzing sample solutions of PCM, CLZ, DCL and FAM at three levels covering low, medium, and high concentrations over a period of 3 days. The peak areas obtained were used to calculate mean and RSD values. Less than 5 % RSD values indicate that the method is precise.

Specificity

Specificity is the ability to assess unequivocally the analyte in the presence of components which may be expected to be present. The specificity of the method was ascertained by analyzing PCM, CLZ, DCL and FAM in presence of excipients commonly used for tablet formulations. The bands of PCM, CLZ, DCL and FAM were confirmed by comparing Rf values and respective spectra of sample with those of standards. The peak purity of PCM, CLZ, DCL and FAM was assured by comparing the spectra at three different levels, that is, peak start, peak apex and peak end positions. Selectivity describes the ability of an analytical method to differentiate various substances in a sample. The proposed method shows well resolution of all four molecules from their pharmaceutical dosage form.

Sensitivity

Sensitivity of the method was determined with respect to LOD and LOQ. Noise was determined by scanning a blank band (methanol) six times. LOD was calculated as 3 times the noise level, and LOQ was calculated as 10 times the noise level.

Robustness

Small changes in the chamber saturation time, solvent migration distance and mobile phase composition were introduced and the effects on the results were examined. Robustness of the method was determined in triplicate at a concentration level of 2000 ng/band for PCM and 1000 ng/spot for DCL and 750 ng/spot for CLZ and FAM. The mean and RSD of peak areas were calculated.

Analysis of marketed formulations

Twenty tablets were weighed accurately and finely powdered. Tablet powder equivalent to 500 mg of PCM, 250 mg of CLZ, 50 mg of DCL and 10 mg of FAM was accurately weighed and transferred to a 100 ml volumetric flask. A few ml (40 ml) of methanol was added to the above flask and flask was sonicated for 15 min. The solution was filtered using what man filter paper No. 41 in another 100 ml volumetric flask and make up the volume up to the mark with the methanol.

A solution containing 300 ng/band FAM and 1500 ng/band DCL were injected as per the above chromatographic conditions and peak areas were recorded. Appropriate volume of the aliquot was transferred to a 10 ml volumetric flask and the volume was made up to the mark with the mobile phase to obtain a solution containing 750 ng/band CLZ and 1500 ng/band PCM. The quantifications were carried out by keeping these values to the straight line equation of calibration curve.

Results and Discussion

Optimization of the Mobile Phase

To develop the HPTLC method for analysis of PCM, CLZ, DCL and FAM in the pharmaceutical dosage form for routine analysis, selection of the mobile phase was carried out on the basis of polarity. A mobile phase that would give a dense and compact band with an appropriate Rf value for PCM, CLZ, DCL and FAM was desired. Various mobile phases such as acetone-methanol, methanol-chloroform acetic acid, methanol-toluene-ammonia, methanol-toluene-glacial acetic acid, toluene-ethyl acetate-methanol, methanol-acetonitrile-glacial acetic acid were evaluated in different proportions. A mobile consisting of chloroform: methanol: ethyl acetate: hexane: ammonia (10: 2.5: 1.5: 1: 0.1, v/v/v/v/v) gave good separation of PCM, CLZ, DCL and FAM from its matrix. It was also observed that chamber saturation time and solvent migration distance were crucial in the chromatographic separation. Therefore, chloroform: methanol: ethyl acetate: hexane : ammonia (10: 2.5: 1.5: 1: 0.1, v/v/v/v/v) mobile phase with a chamber saturation time of 30 min at 25 0C and solvent migration distance of 80 mm was used. Densitogram of PCM, CLZ, DCL and FAM,

photograph of TLC plate and three dimensional overlays of HPTLC densitograms of calibration bands of PCM, CLZ, DCL and FAM are depicted in figures (Figure 1-3).

Validation

Linearity and calibration curves.

The method was found to be linear for PCM in concentration range of 500-3000 ng/band (n = 6) and for CLZ, DCL and FAM 250-1500 ng/band (n = 6), respectively. Figure-3 displays a three-dimensional overlay of HPTLC densitograms of the calibration bands of PCM, CLZ, DCL and FAM at 282 nm. The regression data shown in (Table 1) reveal a good linear relationship over the concentration range studied, demonstrating the suitability of the method for analysis

Accuracy

Accuracy was determined by the application of analytical procedure to recovery studies, where a known amount of standard is spiked into preanalyzed samples solutions. Results of the accuracy studies from excipients matrix are shown in (Table 4). Recovery values demonstrated the accuracy of the method in the desired range.

Precision

In all instances, RSD values were less than 2%, confirming the precision of the method. Repeatability of the scanning device was studied by applying and analyzing sample seven times. RSD was less than 2%, which was well below the instrumental specifications. Summary of validation parameters are shown in (table 2).

Limit of detection and limit of quantification

Under the experimental conditions used, the lowest amount of drug that could be detected LOD was found to be 35.98 ng/band, 99.74 ng/band, 58.63 ng/band and 50.93 ng/band for PCM, CLZ, DCL and FAM, respectively and LOQ was found to be 109.05 ng/band 302.25 ng/band, 177.69 ng/band and 154.35 ng/band for PCM, CLZ, DCL and FAM, respectively. It indicate that the nanogram quantity of all the drugs can be estimated accurately and precisely which means that the method is sensitive.

Specificity

There was no interfering peak at the Rf value of PCM, CLZ, DCL and FAM from excipients added in the synthetic formulation. In addition, there was no interference from excipients present in the commercial formulation, thereby confirming the specificity of the method.

Robustness

The low values of RSD obtained after introducing small, deliberate changes in parameters of the developed HPTLC method confirmed its robustness. The robustness data of the proposed method are shown in (table 3).

Analysis of marketed formulation

Marketed formulation was analyzed using proposed method which gave percentage recovery of 98.46%, 98.26%, 98.09% and 99.01% for PCM, CLZ, DCL and FAM, respectively. No interference from the excipients present in the marketed tablet formulation was observed.

Conclusion

A selective, sensitive, accurate and precise high performance thin layer chromatography method has been developed for the simultaneous identification and quantification of chlorzoxazone, paracetamol, and famotidine and diclofenac potassium in their combined pharmaceutical dosage form. The method was successfully validated in accordance with ICH guidelines. It can be conveniently used for routine quality control analysis of chlorzoxazone paracetamol famotidine and diclofenac potassium in marketed tablet without any interference from excipients.

Acknowledgement

The authors are thankful to Mercury pharmaceuticals Ltd., Baroda and Blue Cross Laboratory, Mumbai, India for providing gift sample of CLZ, PCM, DCL and FAM respectively. The authors are very thankful to Principal, Indukaka Ipcowala College of Pharmacy, and New Vallabh Vidyanagar for providing necessary facilities to carry out research work.

            Figures 1-3: Densitogram of PCM, CLZ, DCL and FAM, photograph of TLC plate and three dimensional overlays of HPTLC densitograms of calibration bands of PCM, CLZ, DCL and FAM are depicted in figures (Figures 1-3).

Tables

PARAMETERS

CLZ

PCM

DCL

FAM

Linearity range (ng/spot)

250-1500

500-3000

250-1500

250-1500

Slope

14.278

5.682

10.902

10.808

Standard deviation of slope

0.2094

0.03033

0.2148

0.294737

Intercept

4619.6

4953.4

9033.6

4310.6

Standard deviation of intercept

155.7122

171.73

193.72

166.82

Correlation coefficient

0.995

0.997

0.995

0.996

Table 1: The regression data shown

Amount of Sample

Set

Amount drug

Average amount recovered (ng/spot)

% Recovery

(ng/spot)

Spiked (ng/spot)

CLZ

PCM

CLZ

PCM

CLZ

PCM

CLZ

PCM

500

1000

1

0

0

495.47

994.47

99.09

99.44

2

0

0

3

0

0

500

1000

1

250

500

747.89

1498.8

99.58

99.88

2

250

500

3

250

500

500

1000

1

500

1000

997.13

1985.6

99.42

98.55

2

500

1000

3

500

1000

500

1000

1

750

1500

1244.1

2489.8

98.81

98.93

2

750

1500

3

750

1500

Table 4: Recovery values demonstrated the accuracy of the method in the desired range.

Amount of Sample

Set

Amount drug

Average amount recovered (ng/spot)

% Recovery

(ng/spot)

Spiked (ng/spot)

FAM

DCL

FAM

DCL

FAM

DCL

FAM

DCL

500

500

1

0

0

496.73

504.38

99.01

100.3

2

0

0

3

0

0

500

500

1

250

250

744.73

749.28

999.6

99.85

2

250

250

3

250

250

500

500

1

500

500

997.75

998.99

98.94

99.79

2

500

500

3

500

500

500

500

1

750

750

1245.07

1246.1

99.34

99.22

2

750

750

3

750

750

 Table 4:Recovery values demonstrated the accuracy of the method in the desired range

PARAMETERS

CLZ

PCM

DCL

FAM

Rf

0.74

0.52

0.29

0.14

Detection limit (ng/spot)

35.98

99.74

58.63

50.93

Quantization limit (ng/spot)

109.05

302.25

177.69

154.35

Accuracy (%)

98.81-99.57

98.55-99.88

99.22-100.27

98.94-99.55

Intra-day (n=3) (% RSD)

1.18-1.249

0.94-1.31

1.33-1.60

0.82-1.06

Inter-day (n=3) (% RSD)

1.71-1.89

1.45-1.68

1.44-1.83

1.57-1.93

Repeatability study (n=6) (% RSD)

1.77-1.96

1.77-1.86

1.71-1.85

1.58-1.83

Table 2: Summary of validation parameters

 Parameters

Amt of CLZ

Amt of ClZ Recovered ± SD

Amt of PCM

Amt of PCM Recovered ± SD

Amt of DCL

Amt of DCL Recovered ± SD

Amt of FAM

Amt of FAM Recovered ± SD

Chamber saturation time : 20 min

750

741±22.9

2000

1960.3±38.07

1000

962.7±31.89

750

766.8±21.65

Chamber saturation time : 40 min

750

753.6±29.50

2000

1941.3±48.22

1000

1014.1±36.90

750

774.9±6.24

Wave length 280

750

762.6±22.85

2000

1943.4±32.71

1000

953.5±28.53

750

780.3±17.92

Wave length 280

750

768.6±17.38

2000

1977.6±12.01

1000

949.6±22.03

750

757.5±10.40

chloroform:methanol:ethayl acetate:hexane:ammonia

750

732.6±10.40

2000

1978.4±34.58

1000

940.2±30.55

750

771.6±23.62

(9: 3.5: 1.5: 1: 0.1v/v/v/v/v)

chloroform:methanol:ethayl acetate:hexane:ammonia

750

771.2±24.57

2000

1952.6±36.115

1000

956.7±19.73

750

748.7±14.9

(11: 2: 1: 1: 0.1 v/v/v/v/v)

Table 3: The robustness data of the proposed method

References

  1. Gopinath R, Rajan S, Meyyanathan SN, Krishnaveni N, Suresh B (2007) A RP-HPCL Method of Simultaneous Estimation of Paracetamol and Aceclofenac in tablets.Ind. J. Pharm. Sci 1: 137-140.
  2. Khatal LD, Rajage AD, More HN, Dhaneshwar SR, Polawar AR (2014) Validated HPLC Method for Simultaneous Quantitation of Paracetamol, Diclofenac Potassium and Famotidine in Bulk Drug and Formulation. Int. J. Pharm. Drug Ana 2: 633-640.
  3. Pawar SJ, Kale AP, Amrutkar MP, Jagade JJ, Pore NS, et al. (2009) HPTLC estimation of Paracetamol, Diclofenac Sodium and Chlorzoxazone in Tablet dosage form. Asian J. Res. Chem 2: 306-308.
  4. Khatal LD, Kamble AY, Mahadik MV, Dhaneshwar SR (2010) Validated HPTLC Method for Simultaneous Quantitation of Paracetamol, Diclofenac Potassium, and Famotidine in Tablet Formulation. J. AOAC Int 93: 765-770.  
  5. Gowramma B, Rajan S, Muralidharan S, Meyyanathan SN, Suresh B (2010) A Validated RP-HPLC Method for Simultaneous Estimation of Paracetamol and Diclofenac Potassium in Pharmaceutical Formulation. Int. J. Pharm. Tech. Res 2: 676-680.
  6. Dighe VV, Sane RT, Menon SN, Tambe HN, Pillai S, et al. (2006) Simultaneous Determination of Diclofenac Sodium and Paracetamol in a Pharmaceutical Preparation and in Bulk Drug Powder by High-Performance Thin-Layer Chromatography. JPC Modern TLC 19: 443-448.
  7. Sharma MC, Sharma S (2011) Determination and Validation of UV-Spectrophotometric Method for Estimation of Paracetamol and Diclofenac Sodium in Tablet Dosage Forms Using Hydrotropic Solubilizing Agents. Int. J. Pharm Tech Res 3: 244-247.
  8. Siddiqui FA, Arayne MS, Sultana N, Qureshi F (2011) Development and Validation of Stability-indicating HPLC Method for the Simultaneous Determination of Paracetamol, Tizanidine, and Diclofenac in Pharmaceuticals and Human Serum. J. AOAC Int 94: 150 - 158.
  9. Shaikh KA, Devkhile AB (2008) Simultaneous Determination of Aceclofenac, Paracetamol, and Chlorzoxazone by RP-HPLC in Pharmaceutical Dosage form. J. Chrom. Sci 46: 649 - 652.
  10. Umarkar AR, Mehta SA, Chaple DR, Thote LT (2011) Simultaneous Estimation of Famotidine and Diclofenac Potassium by UV spectrophotometer Using Multi Component Method. J. Pharm. Res 4: 978-979.
  11. Mehta SA, Umarkar AR, Chaple DR, Thote LT (2011) Development of UV Spectrophotometric Methods for Simultaneous Estimation of Famotidine and Diclofenac Potassium in Combined Dosage form using Simultaneous Equation Method. J. Pharm. Res 4: 2045-2046.
  12. Puranik M, Hirudkar A, Wadher SJ, Yeole PG (2006) Development and Validation of Spectrophotometric Methods for Simultaneous Estimation of Tramadol Hydrochloride and Chlorzoxazone in Tablet Dosage Form. Ind. J. Pharm. Sci 68: 737-739.
  13. Manure JY Md, Aasim G, Sayyed A Md, Tamboli M, Ravetkar AS, et al. (2010) Analytical Method Development of Tramadol Hydrochloride and Chlorzoxazone in Bulk and its Formulation. J. Pharm. Res 3:  2296 - 2302.
  14. Patel J, Patel P (2014) Stability-Indicating RP-HPLC Method for the Determination of Ambrisentan and Tadalafil in Pharmaceutical Dosage Form. Int. J. Pharm. Pharm. Sci 6: 249-256.
  15. Shah DA, Suthar DJ, Baldania SL, Chhalotiya UK, Bhatt KK (2012) Development and Validation of a Liquid Chromatographic Method for Estimation of Dicyclomine Hydrochloride, Mefenamic Acid and Paracetamol in Tablets. Int. Scholarly Res. Notices 6: 1- 5.
  16. Venkatesh K, Vaidhyalingam YG, Nema RK (2009) Simultaneous Estimation of Paracetamol, Chlorzoxazone and Aceclofenac in Pharmaceutical Formulation by HPLC Method. Int. J. ChemTech Res 1: 457-460.
  17. Yadav SS, Jagtap AS, Rao JR (2012) Simultaneous Determination of Paracetamol, Lornoxicam and Chlorzoxazone in Tablets by High Performance Thin Layer Chromatography. Scholars Res. Lib 4: 1798-1802.
  18. Mehta KC, Shyam Kumar B, Dubey A (2012) Development and Validation for Simultaneous Estimation of Famotidine and Diclofenac Potassium in Combined Tablet Dosage Form By First Order Derivative Method. Int. J. Res. Pharm. Chem 2: 1023-1028.
  19. Dhaneshwar SR, Bhusari VK (2011) Validated HPTLC Method for Simultaneous Quantitation of Diclofenac Sodium and Misoprostol in Bulk Drug and Formulation. Asian J. Pharm. Bio. Res 1: 15-21.
  20. Karthik A, Subramanian G, Ranjith Kumar A, Udupa N (2007) Simultaneous Estimation of Paracetamol and Domperidone in tablets by Reverse Phase HPLC Method. Ind. J. Pharm. Sci 69: 142-144.
  21. Rajput MP, Bharekar VV, Yadav SS, Mulla TS, Rao JR (2011) Validated HPCL method for Simultaneous Estimation of Rabeprazole Sodium and Aceclofenac in Bulk Drug and Formulation. Int. J. Comprehensive pharm 12:1- 4.
  22. Nayak S, Sarangi RR, Panda SK, Rath AS, Rath S (2011)  Development and Validation of Simultaneous Estimation of Diclofenac Potassium, Paracetamol and Serratiopeptidase by First Order Derivative UV Spectroscopy Method in Pharmaceutical Formulation. Int. J. Bio & Pharm Res 45-49.
  23. Patel R, Tanna R, Thumar K (2012) HPTLC Method for Simultaneous Estimation of Ibuprofen and Famotidine from Tablet Dosage Form. Pharm. Anal. Qual. Asur 3: 1-6.
  24. Sane RT, Gadgil M (2002) Simultaneous Determination of Paracetamol, Chlorzoxazone, and Nimesulide by HPTLC. JPC - Modern TLC 15: 76-78.
  25. Reddy BP (2009) Simultaneous Estimation of Nimesulide and Chlorzoxazone in Pharmaceutical Formulations by a RP-HPLC Method. Int. J. ChemTech Res 1: 283-285.
  26. Zarghi A, Shafaati SM, Foroutan A, Khoddam (2005) Development of a Rapid HPLC Method for Determination of Famotidine in Human Plasma using a Monolithic Column. J. Pharm. Biomed. Ana 39: 677-680.
  27. Novaković J (1999) High-Performance Thin-Layer Chromatography for the Determination of Ranitidine Hydrochloride and Famotidine in Pharmaceuticals. J Chromatogra 193-198.
  28. ICH [Validation of Analytical Procedures: Methodology (Q2R1)], International Conference on Harmonization, Food and Drug Administration, USA, 1996 & 2005.

© by the Authors & Gavin Publishers. This is an Open Access Journal Article Published Under Attribution-Share Alike CC BY-SA: Creative Commons Attribution-Share Alike 4.0 International License. With this license, readers can share, distribute, download, even commercially, as long as the original source is properly cited. Read More.

Journal of Pharmaceutical and Pharmacological Sciences